Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Electrical & Electronics
Plant Area:
<100 square meters
Main Markets:
North America, South America, Africa
Average Lead Time:
Peak season lead time: within 15 workdays
Off season lead time: within 15 workdays
OEM/ODM Service
Sample Available

Hybrid Module, Philip Module, Catv Amplifier Module manufacturer / supplier in China, offering CATV Hybrid Module (BGY785A), Hybrid Module (BGY888) 860M 34dB, CATV 1310nm Optical Transmitter (GW-OT3000) and so on.

Gold Member Since 2009

CATV Hybrid Module  (BGY785A)

Min. Order: 1 Box
Production Capacity: 10000Pcs/Month
Transport Package: 25PCS/Box, 8boxes/Carton
Payment Terms: T/T, Western Union
Origin: China

You Might Also Like

Loading...

Basic Info.

Model NO.
BGY785A
HS Code
85176229
FEATURES
Excellent linearity
Extremely low noise
Silicon nitride passivation
Rugged construction
Gold metallization ensures excellent reliability.
APPLICATIONS
CATV systems operating in the 40 to 750 MHz
Frequency range.
DESCRIPTION
Hybrid high dynamic range cascode amplifier module in a
SOT115J package operating with a voltage supply of
24 V (DC).

LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).

DEFINITIONS
Data Sheet Status
Objective specification This data sheet contains target or goal specifications for product development.
Preliminary specification This data sheet contains preliminary data; Supplementary data may be published later.
Product specification This data sheet contains final product specifications.
Limiting values
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or
More of the limiting values may cause permanent damage to the device. These are stress ratings only and operation
Of the device at these or at any other conditions above those given in the Characteristics sections of the specification
Is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.

LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices, or systems where malfunction of these
Products can reasonably be expected to result in personal injury. Philips customers using or selling these products for
Use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such
Improper use or sale.

QUICK REFERENCE DATA
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
Gp power gain f = 50 MHz 18 19 dB
F = 750 MHz 18.5 - dB
Itot total current consumption (DC) VB = 24 V - 240 mA.
SYMBOL
 
P ARAMETER
 
CONDITIONS
 
MIN.
 
MAX.
 
UNIT
 
G p
 
power gain
 
f = 50 MHz
 
18
 
19
 
dB
 
f = 750 MHz
 
18.5
 
-
 
dB
 
I tot
 
total current consumption (DC)
 
V B   = 2 4 V
 
-
 
240
 
mA
 








SYMBOL
 
P ARAMETER
 
MIN.
 
MAX.
 
UNIT
 
V i
 
RF input voltage
 
-
 
65
 
dBmV
 
T stg
 
storage temperature
 
- 40
 
+100
 
° C
 
T mb
 
operating mounting base temperature
 
- 20
 
+100
 
° C
 









SYMBOL
 
P ARAMETER
 
CONDITIONS
 
MIN.
 
TY P.
 
MAX.
 
UNIT
 
G p
 
power gain
 
f = 50 MHz
 
18
 
18.5
 
19
 
dB
 
f = 750 MHz
 
18.5
 
19.5
 
-
 
dB
 
SL
 
slope cable equivalent
 
f = 40 to 750 MHz
 
0
 
0.9
 
2
 
dB
 
FL
 
flatness of frequency response
 
f = 40 to 750 MHz
 
-                          
 
± 0.1
 
± 0.3
 
dB
 
S 11
 
input return losses
 
f = 40 to 80 MHz
 
20
 
30
 
-
 
dB
 
f = 80 to 160 MHz
 
18.5
 
29.5
 
-
 
dB
 
f = 160 to 320 MHz
 
17
 
28
 
-
 
dB
 
f = 320 to 640 MHz
 
15.5
 
26
 
-
 
dB
 
f = 640 to 750 MHz
 
14
 
21
 
-
 
dB
 
S 22
 
output return losses
 
f = 40 to 80 MHz
 
20
 
29
 
-
 
dB
 
f = 80 to 160 MHz
 
18.5
 
26
 
-
 
dB
 
f = 160 to 320 MHz
 
17
 
23.5
 
-
 
dB
 
f = 320 to 640 MHz
 
15.5
 
22
 
-
 
dB
 
f = 640 to 750 MHz
 
14
 
24
 
-
 
dB
 
CTB
 
composite triple beat
 
1 10 channels flat; V o   = 44 dBm V;
measured at 745.25 MHz
 
-                          
 
- 54.5
 
- 53
 
dB
 
X mod
 
cross modulation
 
1 10 channels flat; V o   = 44 dBmV;
measured at 55.25 MHz
 
-                          
 
- 57.5
 
- 56
 
dB
 
CSO
 
composite second order distortion
 
1 10 channels flat; V o   = 44 dBm V;
measured at 746.5 MHz
 
-                          
 
- 62
 
- 53
 
dB
 
d 2
 
second order distortion
 
note 1
 
-                          
 
- 77
 
- 65
 
dB
 
V o
 
output voltage
 
d im   = - 60 dB; note 2
 
59
 
62
 
-
 
dBmV
 
F
 
noise figure
 
f = 50 MHz
 
-
 
4.5
 
5.5
 
dB
 
f = 450 MHz
 
-                                
 
-                          
 
5.5
 
dB
 
f = 550 MHz
 
-                                
 
-                          
 
5.5
 
dB
 
f = 600 MHz
 
-                                
 
-                          
 
6                    
 
dB                    
 
f = 750 MHz
 
-
 
6                        
 
7                    
 
dB                    
 
I tot
 
total current consumption (DC)
 
note 3
 
-
 
225
 
240
 
mA
 

Send your message to this supplier

*From:
*To:
avatar Mr. Dennis Song
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now